Hyphen BioMed
BIOPHENâ„¢ FVIII variant
The BIOPHEN Factor VIII variant method involves the chromogenic assay of FVIII cofactor. In the presence of phospholipids (PLPs) and calcium, FVIII, activated by thrombin, forms an enzyme complex with Factor IXa, which activates Factor X. The resulting Factor Xa hydrolyzes the chromogenic substrate, leading to the release of paranitroaniline (pNa). The amount of pNA released (measured by absorbance at 405 nm) is directly proportional to the concentration of FVIII in the specimen (Factor IXa, Thrombin and Factor X are in constant excess amount). The BIOPHEN FVIII variant kit is a variant method of BIOPHEN FVIII where FX is from bovine origin and which is insensitive to Emicizumab.
BIOPHENâ„¢ FXIII
BIOPHEN Factor XIII kit is a chromogenic method proposed for in vitro quantitative determination of Factor XIII activity in human citrated plasma. This kit is for research use only and must not be used for patient diagnosis or treatment.
BIOPHENâ„¢ Bivalirudin Calibrator
In US: For Research Use Only. Not for use in diagnostic procedures. Lyophilized human plasmas, spiked with Bivalirudin at various concentrations, for the calibration of Bivalirudin assays. They are titrated and optimized for the assay of Bivalirudin by anti-IIa clotting and chromogenic techniques.
BIOPHENâ„¢ Bivalirudin Calibrator
In US: For Research Use Only. Not for use in diagnostic procedures. Lyophilized human plasmas, spiked with Bivalirudin at various concentrations, for the calibration of Bivalirudin assays. They are titrated and optimized for the assay of Bivalirudin by anti-IIa clotting and chromogenic techniques.
EASYPLASMAâ„¢ Calibrator
For Research Use Only. The EASYPLASMA Calibrator kit is normal citrated human plasma, lyophilized, intended for the calibration of several coagulation factors assays. It may also be used as normal control plamsa.
BIOPHENâ„¢ Edoxaban Calibrator
In US: For Research Use Only. Not for Use in Diagnostic Procedures. The BIOPHEN Edoxaban Calibrator kit is a set of human plasmas supplemented with Edoxaban at 3 different levels intended for the calibration of Edoxaban measurements, and lyophilized. They are titrated and optimized for anti-Xa chromogenic assays such as BIOPHEN Heparin LRT and BIOPHEN DiXaI. This kit is for research use only and must not be used for patient diagnosis or treatment.
BIOPHENâ„¢ Edoxaban Calibrator Low
In EU: This Product is CE Marked. In Canada: Health Canada Licensed. The BIOPHEN Edoxaban Calibrator kit is a set of human plasmas supplemented with Edoxaban at 3 different levels intended for the calibration of Edoxaban measurements, and lyophilized. They are titrated and optimized for anti-Xa chromogenic assays such as BIOPHEN Heparin LRT and BIOPHEN DiXaI .
BIOPHENâ„¢ Edoxaban Calibrator Low
In EU: This Product is CE Marked. In Canada: Health Canada Licensed. The BIOPHEN Edoxaban Calibrator Low kit is a set of human plasmas supplemented with Edoxaban at 3 different levels intended for the calibration of Edoxaban measurements, and lyophilized. They are titrated and optimized for anti-Xa chromogenic assays such as BIOPHEN Heparin LRT (A221011-CAN, A221013-CAN, A221015-CAN) and BIOPHEN DiXaI (A221030-CAN).
BIOPHENâ„¢ Calibrator FVIIa
In US and Canada: For Research Use Only. Not for Use in Diagnostic Procedures. The BIOPHEN Calibrator Factor VIIa kit is a calibrator for activated Factor VII (FVIIa) activity measurements titrated and optimized using a clotting assay with the HEMOCLOT Factor VIIa (ACK092K-RUO) kit. This kit is for research use only and must not be used for patient diagnosis or treatment.
BIOPHENâ„¢ Apixaban Calibrator
In US: For Research Use Only. Not for Use In Diagnostic Procedures. Lyophilized plasmas, at defined Apixaban concentrations (3 levels of about 0 to 600 ng/mL), as measured with BIOPHEN DiXal (Ref A221030-RUO) or BIOPHEN Heparin LRT (Ref A221011-RUO, A221013-RUO and A221015-RUO), for the calibration of Apixaban measurements using anti-Xa chromogenic assays.
BIOPHENâ„¢ Apixaban Calibrator
In EU: This Product is CE Marked. Health Canada Licensed. Lyophilized plasmas, at defined Apixaban concentrations (3 levels of about 0 to 600 ng/mL), as measured with BIOPHEN DiXal (Ref A221030-CAN)or BIOPHEN Heparin LRT (Ref A221011-CAN, A221013-CAN and A221015-CAN), for the calibration of Apixaban measurements using anti-Xa chromogenic assays.
BIOPHENâ„¢ Apixaban Calibrator Low
In US: For Research Use Only. Not for Use In Diagnostic Procedures. Lyophilized plasmas, at defined Apixaban concentrations (3 levels of about 0 to 100 ng/mL), as measured with BIOPHEN DiXal (Ref A221030-RUO) or BIOPHEN Heparin LRT (Ref A221011-RUO, A221013-RUO and A221015-RUO), for the calibration of Apixaban measurements using anti-Xa chromogenic assays.
BIOPHENâ„¢ Apixaban Calibrator Low
In EU: This product is CE Marked. Health Canada Licensed. Lyophilized plasmas, at defined Apixaban concentrations (3 levels of about 0 to 100 ng/mL), as measured with BIOPHEN DiXal (Ref A221030-CAN) or BIOPHEN Heparin LRT (Ref A221011-CAN, A221013-CAN and A221015-CAN), for the calibration of Apixaban measurements using anti-Xa chromogenic assays.
BIOPHENâ„¢ Rivaroxaban Calibrator Low
In US: For Research Use Only. Not for Use in Diagnostic Procedures. Lyophilized plasmas, at defined Rivaroxaban concentrations (3 levels from 0 to about 100 ng/mL), as measured with the BIOPHEN DiXal (Ref A221030-RUO) or BIOPHEN Heparin LRT (Ref A221011-RUO / A221013-RUO / A221015-RUO), for the calibration of Rivaroxaban measurements using anti-Xa chromogenic assays.
BIOPHENâ„¢ Rivaroxaban Calibrator Low
In EU: This product is CE marked. Health Canada Licensed. Lyophilized plasmas, at defined Rivaroxaban concentrations (3 levels from 0 to about 100 ng/mL), as measured with the BIOPHEN DiXal (Ref A221030-CAN) or BIOPHEN Heparin LRT (Ref A221011-CAN / A221013-CAN / A221015-CAN), for the calibration of Rivaroxaban measurements using anti-Xa chromogenic assays.
BIOPHENâ„¢ Bivalirudin Control
In US: For Research Use Only. Not for use in diagnostic procedures. Lyophilized human plasmas, spiked with Bivalirudin at various concentrations, for the quality control of Bivalirudin assays. They are titrated and optimized for the assay of Bivalirudin by anti-IIa clotting and chromogenic techniques.
EASYPLASMAâ„¢ Control
The EASYPLASMA Control Set is a set of normal and abnormal citrated human plasmas, lyophilized, intended for the quality control of some coagulation factors assays. This kit is for research use only and must not be used for patient diagnosis or treatment.
BIOPHENâ„¢ Edoxaban Control
In US and Canada: For Research Use Only. Not for Use in Diagnostic Procedures. The BIOPHEN Edoxaban Control kit is a set of control plasmas intended for the quality control of Edoxaban measurements, and lyophilized. They are titrated and optimized for anti-Xa chromogenic assays such as BIOPHEN Heparin LRT (A221011-RUO, A221013-RUO, A221015-RUO) and BIOPHEN DiXaI (A221030-RUO). This kit is for research use only and must not be used for patient diagnosis or treatment.
BIOPHENâ„¢ Edoxaban Control
In EU: This Product is CE Marked. The BIOPHEN Edoxaban Control kit is a set of control plasmas intended for the quality control of Edoxaban measurements, and lyophilized. They are titrated and optimized for anti-Xa chromogenic assays such as BIOPHEN Heparin LRT (A221011-CAN, A221013-CAN, 221015-CAN) and BIOPHEN DiXaI (A221030-CAN).
BIOPHENâ„¢ Edoxaban Control Low
In US: For Research Use Only. Not for Use in Diagnostic Procedures. The BIOPHEN Edoxaban Control Low kit is a set of control plasmas intended for the quality control of Edoxaban measurements, and lyophilized. They are titrated and optimized for anti-Xa chromogenic assays (low range) such as BIOPHEN Heparin LRT (A221011-RUO, A221013-RUO, A221015-RUO) and BIOPHEN DiXaI (A221030-RUO). This kit is for research use only and must not be used for patient diagnosis or treatment.
BIOPHENâ„¢ Edoxaban Control Low
In EU: This Product is CE Marked. Health Canada Licensed. The BIOPHEN Edoxaban Control Low kit is a set of control plasmas intended for the quality control of Edoxaban measurements, and lyophilized. They are titrated and optimized for anti-Xa chromogenic assays (low range) such as BIOPHEN Heparin LRT (A221011-CAN, A221013-CAN, A221015-CAN) and BIOPHEN DiXaI (A221030-CAN).
BIOPHENâ„¢ Apixaban Control
In US: For Research Use Only. Not for Use in Diagnostic Procedures. Lyophilized plasmas, at defined Apixaban concentrations (2 levels of about 150 and 300 ng/mL), as measured with BIOPHEN DiXal (Ref A221030-RUO) or BIOPHEN Heparin LRT (Ref A221011-RUO, A221013-RUO and A221015-RUO), for the quality control of Apixaban measurements using chromogenic assays.
BIOPHENâ„¢ Apixaban Control
In EU: This product is CE Marked. Health Canada Licensed. Lyophilized plasmas, at defined Apixaban concentrations (2 levels of about 150 and 300 ng/mL), as measured with BIOPHEN DiXal (Ref A221030-CAN) or BIOPHEN Heparin LRT (Ref A221011-CAN, A221013-CAN and A221015-CAN), for the quality control of Apixaban measurements using chromogenic assays.
BIOPHENâ„¢ Apixaban Control
In EU: This product is CE Marked. Health Canada Licensed. Lyophilized plasmas, at defined Apixaban concentrations (2 levels of about 150 and 300 ng/mL), as measured with BIOPHEN DiXal (Ref A221030-CAN) or BIOPHEN Heparin LRT (Ref A221011-CAN, A221013-CAN and A221015-CAN), for the quality control of Apixaban measurements using chromogenic assays.
BIOPHENâ„¢ Apixaban Control Low
In US: For Research Use Only. Not for Use in Diagnostic Procedures. Lyophilized plasmas, at defined Apixaban concentrations (2 levels of about 25 and 75 ng/mL), as measured with BIOPHEN DiXal (Ref A221030-RUO) or BIOPHEN Heparin LRT (Ref A221011-RUO, A221013-RUO and A221015-RUO), for the quality control of Apixaban measurements using chromogenic assays.
BIOPHENâ„¢ Apixaban Control Low
In EU: This Product is CE Marked. Health Canada Licensed. Lyophilized plasmas, at defined Apixaban concentrations (2 levels of about 25 and 75 ng/mL), as measured with BIOPHEN DiXal (Ref A221030-CAN) or BIOPHEN Heparin LRT (Ref A221011-CAN, A221013-CAN and A221015-CAN), for the quality control of Apixaban measurements using chromogenic assays.
BIOPHENâ„¢ Rivaroxaban Control Low
In US: For Research Use Only. Not for Use in Diagnostic Procedures. Lyophilized plasmas, at defined Rivaroxaban concentrations (2 levels of about 15-35 and 45-105 ng/mL), as measured with the BIOPHEN DiXal or BIOPHEN Heparin LRT, for the quality control of Rivaroxaban measurements using chromogenic assays.
BIOPHENâ„¢ Rivaroxaban Control Low
In EU: This product is CE marked. Health Canada Licensed. Lyophilized plasmas, at defined Rivaroxaban concentrations (2 levels of about 15-35 and 45-105 ng/mL), as measured with the BIOPHEN DiXal or BIOPHEN Heparin LRT, for the quality control of Rivaroxaban measurements using chromogenic assays.
BIOPHENâ„¢ Dabigatran Control Low
In US: For Research use Only. Not for Use in Diagnostic Procedures. Lyophilized plasmas, at defined Dabigatran concentrations (2 levels of about 15-35 and 45-105 ng/mL), as measured with the HEMOCLOT Thrombin Inhibitors kit , for the quality control of Dabigatran measurements with clotting or chromogenic assays.