Hyphen BioMed
CEPHENâ„¢ 5 (8 x 5 mL)
In US and Canada: For Research Use Only. Not for Use in Diagnostic Procedures. For determination of activated Partial Thromboplastin Time (aPTT) on citrated human plasma, using a manual, semi-automated or automated clotting method with liquid reagents ready to use. This reagent has a low sensitivity to Lupus Anticoagulant and can be used for an exploration of Lupus Anticoagulant.
CEPHENâ„¢ 2.5
In US and Canada: For Research Use Only. Not for Use in Diagnostic Procedures. For determination of activated partial Thromboplastin Time (aPTT) on citrated human plasma, using a manual, semi-automated or automated clotting method with liquid reagents ready to use. This reagent has a low sensitivity to Lupus Anticoagulant and can be used for an exploration of Lupus Anticoagulant.
CEPHENâ„¢ 1
In US and Canada: For Research Use Only. Not for Use in Diagnostic Procedures. For determination of activated Partial Thromboplastin Time (aPTT) on citrated human plasma, using a manual, semi-automated or automated clotting method with liquid reagents ready to use. This reagent has a low sensitivity to Lupus Anticoagulant and can be used for an exploration of Lupus Anticoagulant.
GFC Test
The GFC-Test kit is a method for qualitative determination of clot lysis time in human citrated plasma.
HEMOCLOTâ„¢ Factor VIIa
In US: For Research Use Only. Not for Use in Diagnostic Procedures. The HEMOCLOT Factor VIIa kit is a clotting assay for the quantitative determination of Factor VIIa (Activated FVII) activity, in purified medium or citrated plasma, using manual or automated methods.
HEMOCLOTâ„¢ LA-C
In US: For Research Use Only. Not for Use in Diagnostic Procedures. HEMOCLOT LA-C is a dRVV reagent with high phospholipid content to confirm the presence of Lupus Anticoagulants. Diluted Russell’s Viper Venom Test (dRVVT) are simplified reagents for specific detection of lupus anticoagulants (LA), using a manual, semi-automated or automated clotting method.
HEMOCLOTâ„¢ LA-S
In US: For Research Use Only. Not for Use in Diagnostic Procedures. HEMOCLOT LA-S is a simplified dRVV reagent to screen for the presence of Lupus Anticoagulants. Diluted Russell’s Viper Venom Test (dRVVT) are simplified reagents for the specific detection of lupus anticoagulant (LA), using a manual, semi-automated or automated clotting method.
HEMOCLOTâ„¢ Quanti-V-L
In US: 510(k) Cleared for In Vitro Diagnostic Use. Clotting method for the quantitative measurement of Factor V-L (Factor V Leiden) concentration in citrated plasma, by its resistance to the action of Activated Protein C (APC). The assay is performed in the presence of Activated Protein C and Protein S (one single test for each patient). In the presence of APC, the prolongation of clotting time is an inverse relationship of the concentration of Factor V-Leiden (mutation R506Q). Normal Factor V is not measured.
HEMOCLOTâ„¢ VII-X (20 x 1 mL)
In US and Canada: For Research Use Only. Not for Use in Diagnostic Procedures. Assay designed for the specific measurement of combined Factors VII+X in human citrated plasma. The assay measures Factors VII+X in human citrated plasma using a clotting method, triggered with calcium thromboplastin. Highly stable and fully reproducible assay from lot to lot.
HEMOCLOTâ„¢ VII-X (6 x 1 mL)
In US and Canada: For Research Use Only. Not for Us in Diagnostic Procedures. Assay designed for the specific measurement of combined Factors VII+X in human citrated plasma. The assay measures Factors VII+X in human citrated plasma using a clotting method, triggered with calcium thromboplastin. Highly stable and fully reproducible assay from lot to lot.
HEMOCLOTâ„¢ Protein S
In US: For Research Use Only. Not for Use in Diagnostic Procedures. Clotting assay for Protein S anticoagulant activity. Protein S is measured with a clotting method using a Protein S deficient plasma, and coagulation is initiated with FIXa in presence of Activated Protein C (APC) in excess and calcium.
HEMOCLOTâ„¢ Protein S
In US: For Research Use Only. Not for Use in Diagnostic Procedures. Clotting assay for Protein S anticoagulant activity. Protein S is measured with a clotting method using a Protein S deficient plasma, and coagulation is initiated with FIXa in presence of Activated Protein C (APC) in excess and calcium.
HEMOCLOTâ„¢ Protein C
In US: For Research Use Only. Not for Use in Diagnostic Procedures. The HEMOCLOT Protein C is an in vitro method for the quantitative determination of Protein C in human citrated plasma by clotting assay, using a manual or automated method.
HEMOCLOTâ„¢ Protein C
In US: For Research Use Only. Not for Use in Diagnostic Procedures. Protein C is measured with a clotting method, following activation with Protac, a specific activating enzyme extracted from snake venom (Agkistrodon C. Contortrix), in Protein C deficient plasma.
HEMOCLOTâ„¢ Thrombin Time LRT
For Research Use Only. HEMOCLOT Thrombin Time LRT kit is a clotting method for the in vitro qualitative determination of Thrombin Time on citrated plasma.
HEMOCLOT Thrombin Time (T.T.) (6 x 8 mL)
In US: For Research Use Only. Not for Use in Diagnostic Procedures. Reagent for the determination of Thrombin Time (TT) on human citrated plasma, using a clotting method, which can be manual, semi-automatic or automatic. Measurement of the clotting time induced by bovine thrombin, in presence of calcium, on plasma, and exploration of the anti-thrombin activities. Excellent sensitivity to low concentrations of heparin in plasma (from 0.05 to 0.10 IU/mL Unfractionated Heparin (UFH), or from 0.20 IU/mL Low Molecular Weight Heparin (LMWH) in plasma).
HEMOCLOTâ„¢ Thrombin Time (T.T.) (6 x 2 mL)
In US: For Research Use Only. Not for Use in Diagnostic Procedures. Reagent for the determination of Thrombin Time (TT) on human citrated plasma, using a clotting method, which can be manual, semi-automatic or automatic. Measurement of the clotting time induced by bovine thrombin, in presence of calcium, on plasma, and exploration of the anti-thrombin activities. Excellent sensitivity to low concentrations of heparin in plasma (from 0.05 to 0.10 IU/mL Unfractionated Heparin (UFH), or from 0.20 IU/mL Low Molecular Weight Heparin (LMWH) in plasma).
HEMOCLOTâ„¢ Thrombin Inhibitors (3 x 2.5 mL)
In US: For Research Use Only. Not for Use in Diagnostic Procedures. Quantitative assay for measuring direct thrombin inhibitors (DTI), such as Dabigatran, Argatroban, and Hirudin, in human citrated plasma, with a clotting method based on the inhibition of a constant and defined concentration of thrombin.
HEMOCLOTâ„¢ Thrombin Inhibitors (3 x 2.5 mL)
For In Vitro Diagnostic Use. In EU: This Product is CE Marked. Health Canada Licensed. Quantitative assay for measuring direct thrombin inhibitors (DTI), such as Dabigatran, Argatroban, and Hirudin, in human citrated plasma, with a clotting method based on the inhibition of a constant and defined concentration of thrombin.
HEMOCLOTâ„¢ Thrombin Inhibitors (3 x 1 mL)
In US: For Research Use Only. Not for Use in Diagnostic Procedures. Quantitative assay for measuring direct thrombin inhibitors (DTI), such as Dabigatran, Argatroban, and Hirudin, in human citrated plasma, with a clotting method based on the inhibition of a constant and defined concentration of thrombin.
HEMOCLOTâ„¢ Thrombin Inhibitors (3 x 1 mL)
For In Vitro Diagnostic Use. In EU: This Product is CE Marked. Health Canada Licensed. Quantitative assay for measuring direct thrombin inhibitors (DTI), such as Dabigatran, Argatroban, and Hirudin, in human citrated plasma, with a clotting method based on the inhibition of a constant and defined concentration of thrombin.
Bovine Thrombin (6 x 21 NIH)
Research Use Only. Prepared by activation of highly purified prothrombin, in presence of factor Xa, V, and calcium, then specifically purified and stabilized. This is an ON-DEMAND item which requires minimum order quantity and extended lead time. Please Contact Us for a quote.
Bovine Thrombin (1 x 1000 NIH)
Research Use Only. Prepared by activation of highly purified prothrombin, in presence of factor Xa, V, and calcium, then specifically purified and stabilized.
Bovine Thrombin (1 x 21 NIH)
Research Use Only. Prepared by activation of highly purified prothrombin, in presence of factor Xa, V, and calcium, then specifically purified and stabilized.
Purified Bovine Factor Xa (10 x 30 µg)
Research Use Only. Bovine Factor Xa is prepared from highly purified factor X from citrated bovine plasma, activated with agarose bound RVV.
Purified Bovine Factor Xa (1 x 30 µg)
Research Use Only. Bovine Factor Xa is prepared from highly purified factor X from citrated bovine plasma, activated with agarose bound RVV.
AT-Tris Buffer Anti-IIa (Progressive Antithrombin) (1 x 10 mL)
Research Use Only. Buffer containing Tris, sodium chloride and Sodium azide (as preservative). Contains no heparin. This is an ON-DEMAND item which requires minimum order quantity and extended lead time. Please Contact Us for a quote.
AT-Tris Buffer-Anti Xa (Progressive Antithrombin) (1 x 10 mL)
Research Use Only. Buffer containing Tris, sodium chloride and Sodium azide (as preservative). Contains no heparin.
Tris-NaCl-EDTA, ph 7.85 (4 x 20 mL)
Special dilution buffer reducing Heparin Interferences for anti-Xa chromogenic assays, especially using BIOPHEN DiXaI kit or BIOPHEN Heparin LRT kits. This kit is for research use only and should not be used for patient diagnosis or treatment.
Tris NaCI EDTA BSA buffer (pH 8.40)
For Research Use Only. Not for Use in Diagnostic Procedures. Buffer containing Tris (Tris (hydroxymethyl) aminomethane) (0.05M), Sodium Chloride (0.175M), EDTA (7.5mM), BSA (0.2%), and 0.9 g/L Sodium Azide (as preservative). Can be used as buffer recommended by the USP for the assay of heparin anti-IIa activity in combination with BIOPHEN ANTI-IIa (2 Stages Heparin Assay) kit. USP = United States Pharmacopeia. Please see important notification letter from the manufacturer regarding the use of this product.